Contaminant testing is increasingly a critical element of raw-material control, not simply an additional analytical test.
The United States Pharmacopeia (USP) has published for public consultation a proposed revision to General Chapter <469>, Ethylene Glycol, Diethylene Glycol, and Triethylene Glycol in Ethoxylated Substances. The proposal remains unofficial and under consultation. USP notes that Pharmacopeial Forum documents are not suitable for demonstrating compliance and may not ultimately become official.
The proposal reflects a broader regulatory concern that has existed for decades: keeping potentially toxic glycols out of pharmaceutical products through excipients and other raw materials.
Why Does This Matter?
Ethylene glycol (EG) and diethylene glycol (DEG) contamination has been linked to serious and fatal poisoning incidents worldwide. USP notes that EG/DEG contamination of high-risk excipients has been a significant public-health issue since 1937.
The <469> proposal also follows continued FDA attention to this risk, including a February 2023 FDA communication that contributed to further USP work on analytical procedures for these contaminants. In May 2023, FDA issued guidance addressing glycerin, propylene glycol, maltitol solution, hydrogenated starch hydrolysate, sorbitol solution and other high-risk drug components. FDA states that it continues to receive reports of fatal poisonings involving liquid drug products made with DEG- or EG-contaminated components.
The regulatory lesson: A Certificate of Analysis alone does not necessarily eliminate the manufacturer’s responsibility to understand and control a known contaminant risk.
For components susceptible to EG or DEG contamination, FDA has repeatedly emphasized appropriate identity testing and detection of these hazardous impurities before material is used in drug manufacturing.
FDA Expectations are Increasingly Visible in Enforcement
Recent FDA Warning Letters show that this subject is actively evaluated during CGMP oversight. FDA has cited firms for failing to adequately test incoming glycerin, propylene glycol, sorbitol and other high-risk components for DEG or EG contamination. These deficiencies have been tied to 21 CFR 211.84(d)(1), which requires verification of the identity of each component, and FDA has specifically referenced USP tests capable of detecting these impurities.
This is not limited to finished-product manufacturers. FDA has raised similar concerns with suppliers and repackers of pharmaceutical ingredients that did not demonstrate adequate DEG/EG controls.
The trend reinforces a fundamental quality principle: raw-material qualification must consider not only what the material is, but also what foreseeable hazardous impurities could be present in it.
What is USP Proposing Under <469>?
The draft chapter addresses determination of residual:
- Ethylene Glycol (EG)
- Diethylene Glycol (DEG)
- Triethylene Glycol (TEG)
in specified ethoxylated substances, where these compounds may remain as residuals from the manufacturing process.
A significant proposed change is the establishment of two analytical approaches:
- Procedure 1A is the existing approach, with revisions to the substances within its scope. It uses gas chromatography with flame-ionization detection (GC-FID) and a G3 stationary phase.
- Procedure 1B is a newly proposed GC procedure using a G16 column, intended to provide more user-friendly chromatographic conditions for specified ethoxylated materials. USP currently proposes it for materials including polyethylene glycol 40 castor oil, polyoxyl 35 castor oil, polyoxyl 40 hydrogenated castor oil and polyoxyl 15 hydroxystearate.
Procedure 1B also incorporates defined sensitivity and system-suitability expectations, including resolution, tailing, precision and signal-to-noise requirements. These are important controls when testing for trace-level toxic contaminants.
Analytical Readiness at Canadian Analytical Laboratories
Canadian Analytical Laboratories (CAL) has the analytical capability to perform testing according to both proposed Procedure 1A and Procedure 1B of USP <469>. This gives manufacturers, importers, ingredient suppliers and Quality units an opportunity to begin evaluating their materials and analytical-control strategies while the proposed revision moves through consultation.
The proposed revision has not been finalized as an official USP compendial requirement. Organizations should assess the applicability of the draft method in the context of their product, material, regulatory jurisdiction and Quality risk-management program.
The Bigger Quality Question
The real question for industry is not simply: “Does my specification currently require EG/DEG testing?”
A more useful risk-based question is: “Could this raw material reasonably be contaminated with EG, DEG or another hazardous glycol, and what evidence do we have that the risk is adequately controlled?”
That evaluation may involve:
- Supplier qualification
- Material-manufacturing knowledge
- Supply-chain traceability
- Compendial requirements
- Incoming-material testing
- Historical analytical data
- Contaminant risk assessments
- Ongoing supplier monitoring
Recent FDA enforcement shows regulators looking beyond documentation alone and asking whether manufacturers have scientifically adequate controls for foreseeable contamination risks.
For contaminants capable of causing severe toxicity or death, analytical testing is much more than a specification exercise. It is an important component of patient protection.
Resources
GMP Insiders. USP PF 52(5): New General Chapter ⟨1664.5⟩ on Oral Drug Product Leachables, Revised ⟨469⟩ Glycol Test, and General Notices Revisions.
https://gmpinsiders.com/usp-pf-52-5-09-26/
USP — General Chapter ⟨469⟩ Ethylene Glycol, Diethylene Glycol, and Triethylene Glycol in Ethoxylated Substances
https://doi.usp.org/USPNF/USPNF_M6557_10101_01.html
FDA — Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and Other High-Risk Drug Components for DEG and EG — May 2023
https://www.fda.gov/regulatory-information/search-fda-guidance-documents/testing-glycerin-propylene-glycol-maltitol-solution-hydrogenated-starch-hydrolysate-sorbitol
Related Posts
Why EG/DEG Contaminant Testing Is Receiving Renewed Regulatory Attention
Contaminant testing is increasingly a critical element of raw-material control, not simply an additional analytical test. The United States Go to Article
Cross-Contamination Prevention in Multi-Matrix Laboratories
Modern analytical laboratories rarely test a single type of product. On any given day, a lab may analyze botanical Go to Article
The Future of Supplement Testing: How Technology and Innovation Are Reshaping Quality Assurance
For decades, supplement testing in Canada relied on a familiar toolkit. Chromatography for active ingredients. ICP-MS for heavy metals. Microbial Go to Article